TPPep

dots

Urban Telecom Cable
used in local telecom networks
in normal conditions


Number of pairs: from 5 to 600
Wire diameter: 0.4, 0.5, 0.64, 0.7

Cable is produced according to GOST ¹Ð 51311-99 and is intended for laying in cable sewerage systems, collectors, shafts, along walls of buildings and suspension on air telecom lines. Certificate of conformity of Ministry of Telecommunications is available ¹Ä-ÊÁ-0751

Cable has improved electrical parameters (ohm asymmetry is less than 2 per cent), which allow to use it in digital data transmission networks.

· Cable design
· Electrical parameters
· Sprending system
· Wire coloring system

Cable design

 
dots

1. Wire: annealed copper wire.


2. Isolation: foam-skin or special solid polyethylene.


3. Group: two or four isolated wires, sprended into pairs or quands.


4. Sprending: elementary units 10õ2 (5õ4). Main units 50õ2 (25õ4) or 100õ2 (50õ4). Cable core is made by sprending of main units.


5. Polyester isolation: insolative polyester tape.


6. Aluminium screen: Polyethylene-covered aluminium screen is put over polyester isolation along the cable.


7. Sheath: Light-stabilized polyethylene, stable to climate influences.



Electrical parameters, +20° Ñ

 
dots

Electrical resistance to direct current

Wire diameter Electrical resistance to direct current
0.40 mm 139.0 + 9.0 Ohm per 1 km
0.50 mm 90.0 +5.9 -6.0 Ohm per 1 km
0.64 mm 55.0 + 3.0 Ohm per 1 km
0.70 mm 45.0 + 3.0 Ohm per 1 km

Capacity: 45 + 5 nF per 1 km

Ohm asymmetry: not more than 2%

Isolation Resistance, calculated for 1 km of cable:
For 100% of values - not more than 6500 MOhm
Äëÿ 80% of values - not more than 8000 MOhm

Electrical strength:
Wire/wire - 1500 V, 1 min, direct current
Wire/screen - 750 V, 1 min, direct current


Sprending system

 
dots

Number of pairs 10 20 30 50 100
Sprending 2+8 2õ10 3õ10 5õ10 10õ10
Number of pairs 200 300 400 500 600
Sprending 4õ(5õ10) 6õ(5õ10) 8õ(5õ10) 10õ(5õ10) 12õ(5õ10)


Wire coloring system

 
dots

Colors of wires in 10-pair unit Color of elementary unit sprending tape
Ïàðà Color of wire À Color of wire B       Elementary unit number in the main unit Tape color
1           1  
2           2  
3           3  
4           4  
5           5  
6           6  
7           7  
8           8  
9           9  
10           10  
JSC "NEVA CABLES"